365-Day Warranty!
Part Type: 30 Amp Disconnect
Part Number: ICM495-30A
Location: 01A3
Disconnect with Internal Surge Protection
The ICM495 is a UL Listed Electrical Disconnect with an Internal Surge Protective Device built-in. The ICM495 is available in two models 30A Fused and 60A Non Fused. The included Surge Protective Device is intended for 120VAC Single-Phase or 240VAC Split-Phase configurations. Designed to protect equipment from transient surges. The ICM495 is a great low cost option to protect some of the most valuable equipment on the property, including: Air conditioning units, heat pumps, mini-split systems, pool & spa equipment and more…
Protects against
• Lightning strikes
• Power outages & recoveries
• Downed power lines
• Startup of larger equipment
• Equipment failure
• Short circuits and more…
DETAILS:
UL Listed Electrical Disconnect including both enclosure & surge protector
120VAC single-phase, 240VAC split-phase
Features an internal surge protective device
Maximum Surge Current Rating of 100kA
Highest UL rating for nominal discharge current (in 20kA), for increased longevity & durability of the SPD
Constructed with 2 high-quality thermally protected MOV’s (TFMOV)
Completely factory wired for quick and easy installation
NEMA type 3R rated powder coated metal enclosure for indoor/outdoor use
Fully accessible mounting holes, no disassembling required
Braided strap thoroughly grounding both the enclosure and cover
LED indicator light showing when surge protection is operational
30A Fused & 60A non-fused models available
Made in the USA
Limited lifetime product, up to a 3-year $10,000 connected equipment warranty
SPECIFICATIONS:
Service Voltage: Split Phase 240 VAC; 30A at -40°C min. and 25°C max., 240 VAC; 25A at -40°C min. and 55°C max., 240VAC; 60A at -40°C min. and 55°C max.
Short Circuit Current Rating (SCCR): 10 kA
Maximum Surge Current: 100 kA (single event)
Nominal Discharge Current (In): 20 kA (15 multiple events)
SPD Type: Type 2 applications only
Surge Protection Technology: TFMOV
Protection Mode: L1-L2, L1-G, L2-G
Maximum Continuous Operation Voltage (MCOV): L-L: 300 VAC, L-G: 150 VAC
VPR (Vpk): Mode: L-L = 1200, L-N = 700
Input Power Frequency: 50/60 Hz
Diagnostics: Green LED indicates surge protection present
Enclosure Rating: NEMA/Type 3R metal enclosure for outdoor and indoor installation
Installation Point: Located within sight of the motor controller/equipment
Dimensions: 9.0” L x 5.25” W x 2.50” D
Operating Temperature: -40°F to 131°F (-40°C to 55°C)
Operating Humidity: Less than 85%, non-condensing
Operating Altitude: Less than 2000 meters
Agency Certification and Approvals: ANSI/UL1449 5th Edition cULus Listed Device
WEIGHT/DIMENSIONS:
9.00” x 5.25” x 2.50”
REPLACES:
All standard disconnect boxes rated for equal voltage and current configurations
30A – MARS: 83916, RectorSeal: 96417 w/ RSH-50